CanadaInternational

AERA · PERFORMANCE EXPLORER

Temperature changes.
Keep the data precise.

Explore heating points published in the manufacturer catalogue. Each value is tied to its combination and test conditions.

AERA 24

VUH24-VA6BA(O)

Indoor unit : VUH24-VA6BA(I)

Outdoor temperatureHeating capacityConditions
5 °F22,600 BTU/hIndoor: 70 °F DB / 60 °F WB. Outdoor: 5 °F DB / 5 °F WB. Compressor at maximum frequency, per the catalogue note.
17 °F24,000 BTU/hRated conditions: indoor 70 °F DB / 60 °F WB; outdoor 17 °F DB / 15 °F WB.

COP2 at 5 °F : 2.1 W/W

AERA 48

VUH48-VA6BA(O)

Indoor unit : VUH48-VA6BA(I)

Outdoor temperatureHeating capacityConditions
5 °F43,500 BTU/hIndoor: 70 °F DB / 60 °F WB. Outdoor: 5 °F DB / 5 °F WB. Compressor at maximum frequency, per the catalogue note.
17 °F46,000 BTU/hRated conditions: indoor 70 °F DB / 60 °F WB; outdoor 17 °F DB / 15 °F WB.

COP2 at 5 °F : 2.1 W/W

AERA 60

VUH60-VA6BA(O)

Indoor unit : VUH60-VA6BA(I)

Outdoor temperatureHeating capacityConditions
5 °F45,500 BTU/hIndoor: 70 °F DB / 60 °F WB. Outdoor: 5 °F DB / 5 °F WB. Compressor at maximum frequency, per the catalogue note.
17 °F47,500 BTU/hRated conditions: indoor 70 °F DB / 60 °F WB; outdoor 17 °F DB / 15 °F WB.

COP2 at 5 °F : 2.2 W/W

The source and its limits.

VINO catalogue, PDF page 8, printed page 12. Revision and issue date are not stated. Document reviewed October 12, 2026. At 5 °F, the note specifies maximum compressor frequency; at 17 °F, the conditions are rated. These points are not a continuous curve or a load calculation.

AERA 36 remains under review. Full curves and revision confirmation will be requested from the manufacturer before publication.

Open the catalogue source page