Central systems
AERA 60
Made to orderVUH60-VA6BA
A central system that distributes comfort through the building’s ductwork. Compatibility, sizing and configuration must be confirmed for your installation.
Confirm availability and configuration with Altrovia.
Financial assistance in Quebec
LogisVert reference: up to $6,300
This reference amount is associated with the indoor/outdoor combination and AHRI number shown on this page. Eligibility and the final amount depend on the installation date, dwelling, installer, current program rules and the exact combination remaining on Hydro‑Québec’s official list.
- Exact combination
- VUH60-VA6BA(O) + VUH60-VA6BA(I)
- AHRI
- 218361279
- ENERGY STAR
- 4591052
- Review
- Altrovia file · September 2026
Reference amount, not guaranteed.
A rebate is not a discount offered by VINO Canada or Altrovia and cannot be guaranteed before approval by the responsible program administrator.
Is the amount guaranteed?
No. This is a reference amount. The program administrator confirms eligibility and the final amount.
Why must the AHRI number match exactly?
The program evaluates a specific indoor and outdoor unit combination. A different reference may have different performance or eligibility.
When should I submit my application?
Verify current deadlines and required documents directly with the applicable program at the time of installation.
Technical specifications
| Model | VUH60-VA6BA |
|---|---|
| Outdoor unit | VUH60-VA6BA(O) |
| Indoor unit | VUH60-VA6BA(I) |
| Cooling at 95°F (35°C) | 52,500 BTU/h |
| Heating at 47°F (8.3°C) | 54,000 BTU/h |
| SEER2 | 19.6 |
| EER2 · 95 °F | 11.5 |
| HSPF2 · Region IV | 10.8 |
| AHRI file reference | 218361279 |
| AHRI document date | 2026-06-16 |
| ENERGY STAR reference in the Canada summary | 4591052 |
The stated capacities are not low-temperature heating capacities.
TECHNICAL GUIDE
Make sense of the figures.
A few pointers to help you read this sheet and compare models.
Definitions source · U.S. Department of EnergySEER2
Seasonal cooling efficiency rating. Compare this same rating across documented equipment combinations.
HSPF2
Seasonal heating efficiency rating. These sheets specify Region IV: keep this reference when comparing.
Capacity and test temperature
A figure at 47 °F (8.3 °C) is not a low-temperature capacity. Final selection depends on the building assessment and the equipment combination.
Documents & references
Manufacturer documents remain in their original language.
FOR COMPARISON
Within the same range.
View another product sheet or open a comparison with AERA 60.
YOUR PROJECT WITH AERA 60
Prepare the next step.
- Condition of ductwork
- Indoor unit compatibility
- Required capacity and electrical supply
Already own this equipment?
Have the reference and serial number ready for follow-up.
Request support for this model Find its resourcesBEFORE ORDERING
Availability, lead time and warranty.
Confirm your order
Share your model, region and timeline. Altrovia will confirm availability, estimated lead time and configuration in your quote.
Check availabilityGet the written terms
Ask for applicable parts and labour coverage periods, exclusions, possible charges and the claim process for this model.
Request warranty termsVINO CANADA
Your next project starts here.
Our team helps connect your project with the right solution and contact.
™